[es:puerta acustica RS-BASIC 41dB][en:RS-BASIC 41dB acoustic door][fr:Porte acoustique RS-BASIC 41dB][de:Schallschutztür RS-BASIC 41dB]
RS5FS – 41 dB
21 April, 2017
RS8 – 43 dB
27 April, 2017

RS6 – 38 dB

Acoustic Steel Door

without lower threshold

Metal acoustic door of the RS range, consisting of high-performance
acoustic doors with certified acoustic insulation. Own manufacture

Features

Acoustic door without bottom frame and slide lock. Available in single and double leaf. Standard models and special sizes. Wide range of accessories .

 Applications

Radio stations, studios, post production, home cinema, offices, shops, meeting rooms, music schools, educational centres.

 

Special Accessories (upon order)

Viewer, exposed lock, push-bar.

TECHNICAL DATA

Description: 69 mm thick acoustic door, consisting of a 12 mm thick polished sheet metal frame and leaf, filled with sound-absorbing materials. Fitted with double perimeter weather-stripping.
Without bottom frame. Innertia hinges.
Closure: Sliding, stainless steel.
Hinges: Inertia hinges.
Surface treatment: Synthetic primer (for painting).
Optional accessories: Sight glass, visible lock, panic lock, cylinder for lock, lower threshold.
Thermal transmittance Ud: 1,93 W/m²K.
Acoustic certificate: Valid for door without accessories

Without lower threshold RS
Overall sound reduction index , Rw (C;Ctr): 38 (-2;-3) dB
Overall weighted sound reduction index A, RA: 37,2 dBA

STANDARD DIMENSIONS

Single leaf (W x H in mm)

Model Interior Dimension Exterior Dimension
RS6/01 800 x 2.000 920 x 2.060
RS6/02 900 x 2.000 1.020 x 2.060
RS6/03 1.000 x 2.000 1.120 x 2.060

Double leaf (W x H in mm)

Model Interior Dimension Exterior Dimension
RS6/21 (*) 1.400 x 2.000 1.520 x 2.060
RS6/22 1.600 x 2.000 1.720 x 2.060
RS6/23 1.800 x 2.000 1.920 x 2.060
RS6/24 2.000 x 2.000 2.120 x 2.060

(*) Unequal leaves (800+600) for RS6/21

ASSEMBLY INSTRUCTIONS

About metallic pre-frame

Firmly x the metallic pre-frame to the partition wall or the gyp- sum. Move the acoustic door (frame and leaf), always closed, towards the inside space of the pre-frame and shim the door until it is level. Spot weld for the rst time between the door and the pre-frame and check the vertical and horizontal levelling, do not open until de nitive welding has been nished. Carry out nal welding between the door and the pre-frame, once again check the levelling and open the door to verify that it works correctly. Seal the spans that remain between the pre-frame rim and door with insulating polyurethane foam or acrylic putty if there is just a little space. Keep the door closed as much as possible.

How to use

– Fitted with pressure handle: To open rmly grip the handle, turn it clockwise and push the leaf; to close it, rmly grip the handle, bring the leaf towards the rim and only then turn the handle anti-clockwise until it is closed.
– Fitted with latch handle: To open grip the handle, turn it clockwise and push the leaf; to close it, grip the handle and bring the leaf towards the rim.
– Fitted with panic bar: To open, push the bar downwards and push the leaf; to close it, grip the bar or handle and bring it towards the rim.

Use restrictions

Do not hit the door with anything that could deform it. Once the leaf is open don’t hang on it. Close the leaf gently without banging.

Preventive maintenance

We recommend an annual service, therefore Acústica Integral o ers a contract in which we service: Mobile door elements ( Hinges, handles and locks): cleaning, oiling, regulation and checking of good working order of all parts. Draught excluders and intumescent joints: substitution of damaged or badly working parts. Checking for looseness.

Diagrams / Plans

RELATED PROJECTS

Your compare list

Compare
REMOVE ALL
COMPARE
0